ALL200RM-230V
INSTALLATION
INSTRUCTIONS
Aladdin Light Lift, Inc. (256) 429-9700
61 Shields Road (877) 287-4601
Huntsville, AL 35811 www.aladdinlightlift.com
Patent #5105349
WARNING: Disconnect power source before servicing to avoid electrical shock
CAUTION: To Reduce the Risk of Electric Shock or Injury, Use Indoors Only.
Light and motor circuits are rated at AC 230V
Pour usage seulement dans un endroit
Avec acces au dessus du plafonds
Model Number: ALL200RM (90.9 Kg rated working load, 1/8” steel galvanized lay cable,
1.5amp, 50/60Hz)
Light lift is equipped with a 65’ (19.8m) cable unless checked below:
______90’ (27.4m)
______120’ (36.6m)
Light lift is equipped with a 1,650 watt (15 amps)
lighting capacity unless checked below:
______2200 watts (20 amps)
________________________
Manufacture Date © 2012 All Rights Reserved
Vista de página 0
1 2 3 4 5 6 ... 20 21

Resumo do Conteúdo

Página 1 - INSTRUCTIONS

ALL200RM-230V INSTALLATION INSTRUCTIONSAladdin Light Lift, Inc. (256) 429-970061 Shields Road (877) 287-4601Huntsville, AL 35811 www.al

Página 2 - ALL200RM Parts Bag List

STEP 13After turning o power, remove and discard existing electrical box if present in ceiling. Only use ceiling box provided with ALL200RM.Never re

Página 3 - ALL200 RM Hardware Box List

STEP 17Attach conduit assembly to 3/4” conduit connector mounted below chandelier pulley. Once completely inserted, tighten set screw on conduit conn

Página 4 - Left Angle

STEP 20Loosely fasten chandelier pulley assembly to suitable structure using 7/16” x 4” hex tap bolts, 7/16” nylon lock nuts and 3/8” USS at washers.

Página 5

STEP 22Shim and adjust chandelier pulley assembly so that winch cable hangs plumb through center of hole in top contact plate on ceiling box. See Dia

Página 6

STEP 25Turn o supply power before wiring ALL200RM light switch. Turn o light switch in square box. Wire light switch with 230V wiring. e 230V li

Página 7

STEP 26Run controller wire in to single gang box for Keyswtich Controller or optional SmartLift Controller. Chandelier must be visible from controll

Página 8

STEP 31Fully thread screw collar loop or threaded stem that was supplied with chandelier to 1/4 IPS(13mm) xture coupler. If chandelier was supplied

Página 9

STEP 34Adjust screw collar rings so top of canopy is just below edge of bottom contact plate. Canopy should be at least 4.4cm deep. See Diagram R.Ne

Página 10

STEP 38Tighten xture coupler set screws using supplied 3/32” Allen wrench. Fixture coupler set screws have thread lock already applied at factory.

Página 11 - SheetrockSheetrock

STEP 41Conrm winch cable still hangs plumb through center of hole in top contact plate on ceiling box. See STEP 22 and Diagram M.STEP 42Operate ALL2

Página 12

Read the following guidelines prior to installing the ALL200RM:I. e ALL200RM must be installed by a licensed, bonded, and insured electrician. II. 

Página 13 - Suitable Structure

ALL200RM TROUBLESHOOTING GUIDETECH SUPPORT: (877) 287-4601 Monday through Friday 8:00am to 4:00pm US CSTI. Troubleshooting and installation must be p

Página 14

ALL200RM TROUBLESHOOTING GUIDE cont. 1. Conrm ALL200RM is at the CEILING POSITION. If not, use the controller to operate the ALL200RM to the CEILIN

Página 15

ALL200 RM Hardware Box List5/16” USS Flat Washers (QTY 4)3/8” x 1¼” Hex Tap Bolts (QTY 2)Flat Brackets (QTY 2) per directional pulle

Página 16

STEP 1Determine mounting location of ALL200RM motor assembly. e ALL200RM may be mounted on an angle, vertically, horizontally or upside down, if sec

Página 17

STEP 3Determine mounting location of directional pulleys if they are to be installed with ALL200RM. Directional pulleys can be used to change winch c

Página 18

STEP 6Position ALL200RM motor assembly where it will be mounted. Adjustments can be made loosening 3/8” channel strut bolts that hold ALL200RM motor

Página 19

STEP 8Turn o supply power before wiring ALL200RM motor switch. Turn o motor switch in square box. Wire motor switch with 230V wiring. e 230V moto

Página 20

STEP 9Remove dust cover by using 5/16” nutdriver or socket. Remove paper tape from winch drum while keeping tension on winch cable.Never operate the

Página 21 - Warranty Agreement

Diagram HRemove Dowel Pin Grooved End FirstInsert Dowel Pin Smooth End FirstFixture CouplerTemporary WeightBottom Contact Plate AssemblyWinch Cable